Registration Dossier

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
Qualifier:
according to
Guideline:
EU Method C.4-D (Determination of the "Ready" Biodegradability - Manometric Respirometry Test)
Qualifier:
according to
Guideline:
EPA OPPTS 835.3110 (Ready Biodegradability)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic (adaptation not specified)
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
30 mg/L
Based on:
test mat.

Results and discussion

% Degradation
Parameter:
% degradation (O2 consumption)
Value:
0
Sampling time:
28 d

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
under test conditions no biodegradation observed