Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data from peer-reviewed handbook or collection of data.

Data source

Reference
Reference Type:
review article or handbook
Title:
Reaxys ID 605969
Author:
Reaxys
Year:
2014
Bibliographic source:
https://www.reaxys.com/reaxys/secured/start.do
Report Date:
2014

Materials and methods

GLP compliance:
no
Type of method:
other: no data

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid
Details on test material:
- Purity not reported
- Empirical formula: C6H6ClN
- Molecular mass: 127.58 g/mole

Results and discussion

Viscosityopen allclose all
Temp.:
other: 25.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
3.5
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.35
Remarks on result:
other: (kinematic)

Any other information on results incl. tables

Result:

dynamic Viscosity

 Kind of measurement  Poise [P]  mPa*s  Temperature [°C]
 Ostwald's viscosity  0.042556  4.23  29.99
   0.03495  3.5  25
   0.01764  1.76  55

3 various authors

kinematic viscosity

 Stokes [St]  mm²/s  Temerature [°C]
0.033538   3.35  20
 0.020285  2.03  40
 0.013939  1.39  60
 0.010387  1.04  80

Dreisbach; Advances in Chemistry Series; nb. 15; (1955); p. 348,

Applicant's summary and conclusion

Conclusions:
The dynmaic viscosity of 3-chloroaniline was measured as 3.5 mPa*s at 25 °C and the kinematic viscosity as 3.35 mm²/s at 20 °C.
Executive summary: