Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study with acceptable restrictions (e.g. non-GLP)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002. Remark: DIN EN ISO 2719 / ASTM D93-07
Type of method:
closed cup
Remarks:
HFP 360 Pensky Martens Closed Cup

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of 2-methyldecan-1-al and undecanal
EC Number:
907-235-6
Molecular formula:
not applicable-Multi constituent
IUPAC Name:
Reaction mass of 2-methyldecan-1-al and undecanal
Details on test material:
Productname: n/i-Undecanal
CAS-Nummer: 112-44-7 / 19009-56-4
Purity (GC): 97,9 % n/i-Undecanale gemäß GC-Analyse vom 21.02.2013
Source: Tank 23 vom 08.08.2012
LIMS-ID: 20121206105539

Results and discussion

Flash point
Flash point:
101 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Conclusions:
Flash Point: 101 °C
Executive summary:

Flash Point: 101 °C