Registration Dossier

Administrative data

Link to relevant study record(s)

Description of key information

Ignition on contact with air: no
Release of flammable gas in contact with water: no

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

One key (Klimisch score=1) flammability study (according to EU method A.10) was identified for FEXO-07.

Two tests were performed: on each test, the same sample behaviour was observed. The sample tested did not ignite, but it melted and became yellow-brown when the Bunsen's burner flame was approached. At room temperature it became a solid glassy. The combustion did not propagate, therefore no further testing was required.

Justification for classification or non-classification

Based on evaluation of the flammibility data discussed above, FEXO-07 does not meet the criteria for classification as flammable under the CLP Regulation (Regulation (EC) n. 1272/2008) and the Directive 67/548/EEC because the sample tested did not ignite.