Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13/11/2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO No., other: OECD 103
Principles of method if other than guideline:
The flash point determination of test substance Triethyl phenyl phosphonium bromide (CAS No. 1530-32-1) was done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Name of test material : Ethyltriphenylfosfonium bromide
- Molecular formula : C20H20P.Br
- Molecular weight : 371.256 g/mol
- Smiles notation : [P+](c1ccccc1)(c1ccccc1)(c1ccccc1)CC.[BrH-]
- InChl : 1S/C20H20P.BrH/c1-2-21(18-12-6-3-7-13-18,19-14-8-4-9-15-19)20-16-10-5-11-17-20;/h3-17H,2H2,1H3;1H/q+1;/p-1
- Substance type: Organic
- Physical state: Solid
- Physical Appearance: white powder
- Purity: 98.6%
- Storage Conditions: 1. Ambient Temp (23 to 27 °C) √ (Store in a cool place. Keep containers tightly closed in a dry and well ventilated place)
Key result
Flash point:
> 180 °C
Atm. press.:
980.2 hPa
Remarks on result:
other: No other detail available

TEST DESCRIPTION AND RESULT

Method Details

Observations

Remarks if, any

Guideline

OECD 103

 

 

Method

Closed cup method using Pensky Martin’s Flash Point Apparatus

 

 

Principle of Flash point test

The flash point of a flammable liquid is the lowest temperature at which there will be enough flammable vapor to ignite when an ignition source is applied.

 

 

Type of method

·    Closed cup

 

 

Flash point apparatus

·    Abel’s flash pt apparatus

·    Pensky – Martin’s flash point apparatus

Pensky – Martin’s flash point apparatus

 

Volume of chemical used

Ml/gm

10 gm

 

Ignition source

Gas lighter/flame

Gas lighter

 

Atmospheric pressure

hPa

980.2 hPa

 

Flash point (RESULT)

°C

180 °C

 

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point determination of test substance Ethyltriphenylfosfonium bromide (CAS No. 1530 -32 -1)was done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test substance was determine to be greater than 180°C at 980.2 hPa.
Executive summary:

The flash point determination of test substance Ethyltriphenylfosfonium bromide (CAS No. 1530 -32 -1)was done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The flash point of the test substance was determine to be greater than 180°C at 980.2 hPa.

Description of key information

The flash point determination of test substance Ethyltriphenylfosfonium bromide (CAS No. 1530 -32 -1)was done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test substance was determine to be greater than 180°C at 980.2 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
180 °C

Additional information

The flash point determination of test substance Ethyltriphenylfosfonium bromide (CAS No. 1530 -32 -1)was done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test substance was determine to be greater than 180°C at 980.2 hPa.

From other authoritative databases flash point of Ethyltriphenylfosfonium bromide (CAS No. 1530-32-1) is determine to be greater than 200 Deg C.