EC number: 467-080-0 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
symptoms develop seek medical attention immediately. If not
breathing, give artificial respiration.
Emergency measure - Eyes: Rinse eyes with plenty of water, also under the eyelids.
Remove any contact lenses and continue washing with running
water for at least 15 minutes. If irritation persists seek
medical attention.
Emergency measure - Skin: Wash materials off the skin and wash with soap and plenty of
water for several minutes. If irritation persists seek
medical attention.
If in contact with hot polymer cool skin rapidly with cold
water. Do not peel polymer from the skin.
Emergency measure - Ingestion: Never give anything by mouth to an unconscious person. If a
large amount is swallowed seek medical advice immediately
and show the doctor the packaging or label.
Fire-fighting measures
Product arising from burning: If involved in a fire oxides of carbon will be formed.
Product determined by test: N
Protective equipment: Full protective clothing and self-contained breathing
apparatus must be worn.
Accidental release measures
Wear appropriate personal protective equipment conforming to
the relevant national or international standards.
Carefully transfer the spillage to waste containers, or use
a sealed industrial vacuum machine. Containers filled with
waste material must be labelled in the same way as the
original containers.
Clean the spillage area with water and detergent.
Dispose of waste material by incineration or landfill in
accordance with local regulations.
Handling and storage
conditions of good industrial hygiene and in conformity with
any local regulations in order to avoid exposure.
Engineering controls are necessary to reduce exposure to the
substance.
When exposure cannot be prevented or adequately controlled
appropriate personal protective equipment should be worn.
Such protective equipment should conform to the appropriate
international or national standards as follows;
Chemical protective gloves to Standard EN374
Chemical resistant clothing to Standard EN368
Eye protection to Standard EN166
When necessary appropriate respiratory protection should be
used. e.g. a dust mask conforming to EN149FFP1.
The standards mentioned above should be regarded as a
minimum.
Storage: Store in a well-ventilated area away from heat and sunlight.
Recommended storage temperature is between 0 and 40 deg C.
Keep containers tightly closed when not in use.
Packaging of the substance and or preparation: 10, 15 or 25 kg bags or small boxes.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport code: None
Transport: The substance is not classified as a dangerous material for
transportation. No specific precautions are needed.
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Stability and reactivity
Chemical reaction with water: None
Dust explosion: Based on molecular structure and composition of the
substance, explosives properties are not expected but based
on particle size, dust explosion potential can not be
excluded. See MSDS section 9.2 (Annex 7).
Potential explosive properties are indicated by the presence
of certain reactive groups in the molecule and /or by the
oxygen blanace. The molecular structure does not indicate
that such groups are present. No combination of
oxidizing and organic components, which may also indicate
potential explosive properties is present. Therefore,
considering the molecular structure and composition of the
substances, explosive properties are not expected.
Precautions regarding dust explosion risk are indicated in
following sections of the MSDS 5,6,7, 9& 10.
Dust explosion determined by test: N
Disposal considerations
minor spillages or accidental discharge is not economically
or technically feasible, and such waste material will be
disposed of by incineration or landfill. In principle, it
may be possible to recover larger spillages of
uncontaminated material for subsequent use.
Industry - Possibility of neutralisation: Not known.
Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of solutions mixed with
inert material (eg sand or soil) may be disposed of by
landfill at an authorised tip in accordance with local
regulations.
Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning
under controlled conditions at a licensed waste treatment
processor in accordance with local regulations. Stack gases
should be scrubbed, because noxious fumes such as oxides of
carbon could be formed.
Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to
the sewage system or the aqueous environment. However,
adverse effects on sewage treatment systems would be
unlikely.
Public at large - Possibility of recovery/recycling: Not applicable.
Public at large - Possibility of neutralisation: Not applicable.
Public at large - Possibility of destruction: controlled discharge: Not applicable.
Public at large - Possibility of destruction - incineration: Not applicable.
Public at large - Possibility of destruction - water purification: The substance should not be discharged directly to the
sewage system or the aqueous environment.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.