Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to method A.1 and GLP compliant.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
yes
Type of method:
thermal analysis
Remarks:
Differential Scanning Calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Melting / freezing pt.:
>= 55 - <= 65 °C
Atm. press.:
ca. 1.013 atm
Decomposition:
no
Remarks on result:
other: The endothermic signal results in a 58.1°C onset temperature.

Applicant's summary and conclusion

Conclusions:
Melting point is 58.1°C