Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove to fresh air. Consult a physician if unwellness
persists.
Emergency measure - Eyes: Flush with plenty of water. Consult a physician in case
irritation persists.
Emergency measure - Skin: Wash with water and soap.
Emergency measure - Ingestion: Give water to drink. Do not induce vomitting. Consult a
physician if unwellness persists.

Fire-fighting measures

Recommended extinguishing agent: Water, watermist, foam, powder, CO2

Product arising from burning: Oxides of carbon and nitrogen

Product determined by test: N

Protective equipment: Self contained breathing apparatus in case of fire

Accidental release measures

Emergency measures in case of spillage: Sweep up with sand or another absorbing material and dispose
in conformity with local/national regulations.

Handling and storage

Handling: Avoid excessive dusting

Use in well ventilated place in abscence of sparks / open
fire

Storage: Keep containers / packaging closed.

Store in a dry place at ambient temperature in original
container.

Keep away from oxidising materials

Packaging of the substance and or preparation: Keep in the original packaging. Keep packaging closed.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No particular recommendations
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: No particular ones

Chemical reaction with water: No reactions to expect.

Dust explosion: May cause dust explosion in the finely divided state in the
air

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: No satisfactory method known once the substance has been
dissolved in an oil

Industry - Possibility of neutralisation: No satisfactory methods known.Controlled incineration is
recommended.

Industry - Possibility of destruction: controlled discharge: Controlled discharge on a land fill in conformity with
local/national regulations may be considered but is not
recommended

Industry - Possibility of destruction - incineration: Controlled inciniration with recovery of energy is
recommended

Industry - Possibility of destruction - water purification: Disposal via sewer is not recommended. Purification by
sedimentation may be recommended.

Industry - Possibility of destruction - other: None

Public at large - Possibility of recovery/recycling: Not applicable

Public at large - Possibility of neutralisation: Not applicable

Public at large - Possibility of destruction: controlled discharge: Not applicable

Public at large - Possibility of destruction - incineration: Not applicable

Public at large - Possibility of destruction - water purification: Not applicable

Public at large - Possibility of destruction - others: None