Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2004
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Type of method:
closed cup

Test material

Constituent 1
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
89 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion