Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air. Symptomatic treatment.
Emergency measure - Eyes: Rinse with eyewash solution or clean water, holding the
eyelids apart for at least 10 minutes. Obtain medical
attention.
Emergency measure - Skin: Wash with water. If symptoms develop, obtain medical
attention.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water spray, foam, dry powder or carbon dioxide may be used.

Product arising from burning: Products of combustion may contain oxides of carbon,
nitrogen and sulfur together with some soot and metal oxide
smoke.

Product determined by test: N

Protective equipment: A self-contained breathing apparatus and suitable protective
clothing should be worn.

Accidental release measures

Emergency measures in case of spillage: Wear suitable protective clothing (see 2.3.1).

Take up spill and transfer to a suitable labelled container.
Dispose of by incineration in accordance with local
regulations. Wash spill site with water.

Handling and storage

Handling: Avoid dust formation. Avoid contact with skin and eyes.
Avoid inhalation of high concentrations of dust. Gloves,

safety goggles and suitable respiratory protection should be
worn.

Storage: Store in tightly closed containers.

Take precautionary measures against static discharges.

Packaging of the substance and or preparation: 25 kg mild steel full opening drum with polyethylene liner.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Take precautionary measures against static discharges.

Chemical reaction with water: None reported.

Dust explosion: In common with many organic compounds in powder form it can
produce flammable dust clouds in air.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not economically feasible.

Industry - Possibility of neutralisation: Not applicable.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Recommended method at a suitable facility. Waste gas
treatment to remove oxides of nitrogen and sulfur and metal
oxide smoke should be fitted. (A661)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: Recovery from printed documents is not feasible.

Public at large - Possibility of neutralisation: Not applicable at the concentration levels used.

Public at large - Possibility of destruction - others: Printed documents may be disposed of as for domestic waste.