Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
density
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 - 20 Mar 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP - Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
GLP compliance:
yes (incl. QA statement)
Remarks:
Landesamt fűr Umwelt, Wasserwirtschaft und Gewerbeaufsicht Kaiser-Friedrich-Straße 7, 55116 Mainz
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
- Name of test material (as cited in study report): Sulfonium, tris(4-chlorophenyl)-, salt with 5-benzoyl-4-hydroxy-2-methoxybenzenesulfonic acid (1:1)
- Physical state: Whitish/Crystalline powder
- Lot/batch No.: 14-121
- Expiration date of the lot/batch: 01 Jun 2016
- Storage condition of test material: at room temperature protected from light

Results and discussion

Density
Type:
density
Density:
> 1.469 - < 1.469 g/cm³
Temp.:
20 °C

Any other information on results incl. tables

Results

Results of the single determinations with the respective error as well as the mean value and its standard deviation are presented in the following tables.

 

Table 1: Results of single determinations

Determination

Density in g/cm3

Error of determination in g/cm3

1

1.4706

0.0003

2

1.4673

0.0003

 

Table 2: Results – Mean values

Parameter

Value

Unit

Standard Deviation

Relative Standard Deviation

Volume of pycnometer

50.36

cm3

0.0100

0.02%

Density of test item

1.4689

g/cm3

0.0024

0.16%

Density of test item

1468.9

kg/cm3

2.4

0.16%

Relative density of test item

1.4689

 

0.0024

0.16%

 

DISCUSSION

The density of the test item Sulfonium, tris(4-chlorophenyl)-, salt with 5‑benzoyl‑4‑hydroxy‑2‑methoxybenzenesulfonic acid (1:1) was calculated as 1.4689 ± 0.0003 g/cm3at 20 ± 0.4 °C, which is the mean of two values. Precision of the value is given as maximal error of a single determination.

Applicant's summary and conclusion