Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 28, 2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report date:
2003

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
1999
Principles of method if other than guideline:
According to REACH Article 13(3) tests on substances shall be conducted in accordance with the test methods laid down in a Commission Regulation or in accordance with other international test methods recognised by the Commission or the Agency as being appropriate. No particle size distribution test method is laid down in regulation (EC) No 440/2008. OECD 110 TG ‘Particle Size Distribution/FibreLength and Diameter Distributions’ dates from 1981 and describes two methods in detail; both methods have restrictions and are not applicable to the entire size range. ECHA’s Guidance on information requirements and Chemical Safety Assessment-Chapter R.7a stipulates that many methods are available for particle size measurements but none of them is applicable to the entire size range. The guidance mentions Laser scattering/diffraction as a method for particles of all kind and makes reference to ISO 13320. The MMAD can be calculated when density is known.
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution

Test material

Constituent 1
Reference substance name:
2,4-bis[N'-(4-methylphenyl)ureido]toluene
EC Number:
411-790-5
EC Name:
2,4-bis[N'-(4-methylphenyl)ureido]toluene
Cas Number:
54390-87-3
Molecular formula:
C23H24N4O2, C24H34N4O2
IUPAC Name:
3-(2-methyl-3-{[(4-methylphenyl)carbamoyl]amino}phenyl)-1-(4-methylphenyl)urea; 3-(2-methyl-5-{[(4-methylphenyl)carbamoyl]amino}phenyl)-1-(4-methylphenyl)urea; 3-{2-methyl-3-[(octylcarbamoyl)amino]phenyl}-1-(4-methylphenyl)urea
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study report): KY-MA
- Batch No.: 4BT079M
- Expiration date of the batch: February 14, 2004
- Appearance: white to light pink powder
- Storage condition of test material: at room temperature in the dark
Specific details on test material used for the study:
Relative density: 1.22

Results and discussion

Mass median aerodynamic diameter:
468 µm
Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
47.12 µm
St. dev.:
3.44
Percentile:
D25
Mean:
187.8 µm
St. dev.:
3.44
Key result
Percentile:
D50
Mean:
423.8 µm
St. dev.:
3.44
Percentile:
D75
Mean:
643.6 µm
St. dev.:
3.44
Percentile:
D90
Mean:
784.4 µm
St. dev.:
3.44
Particle size distribution at different passages
Size:
< 10 µm
Distribution:
3.09 %
Remarks on result:
other: average of 3 runs

Any other information on results incl. tables

Manual sieve analysis

Sieve Size (μm)

Weight (g)

By weight [%]

Sieve

Sieve & Powder

Powder

>1000

369.0

395.1

26.1

26.1

850-1000

378.5

384.7

6.2

6.2

<850

242.0

309.7

67.7

67.7

Laser diffraction particle size analysis (sample tested: < 850 µm)

 

RUN 1

RUN 2

RUN 3

Average

Volume %

100.0

100.0

100.0

100.0

Mean (µm)

284.8

285.7

254.4

274.5

Median (µm)

440.2

438.4

391.7

423.8

Mode (µm)

716.7

716.7

716.7

716.7

95% Conf. Limit (µm)

26-3120

26.2-3110

21.4-3030

24.4-3090

S.D.

3.39

3.38

3.54

3.44

Applicant's summary and conclusion

Conclusions:
Manual sieve analysis showed that 67.7% (w/w) of the substance had a particle size of < 850 μm. Laser diffraction results for the substance fraction < 850 µm:
D10 = 47.12 µm, D50 = 423.8 µm and D90= 784.4 µm. 3.09 % by volume was determined to be < 10.00 μm. The MMAD was calculated to be 468 µm.
Executive summary:

According to BS ISO 13320-1: 1999 and GLP principles the particle size distribution of the substance was determined using laser diffraction analysis

(dry powder module). Manual sieving was performed on 1000 and 850 µm sieves. 67.7% (w/w) of the substance had a particle size of < 850 μm. Laser diffraction results for the substance fraction < 850 µm:

D10 = 47.12 µm, D50 = 423.8 µm and D90= 784.4 µm. 3.09 % by volume was determined to be < 10.00 μm. The MMAD was calculated from D50 and density to be 468 µm.