Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 February 2020 to 12 March 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
13 April 2004
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: EU Method A.24 (Partition Coefficient (n-octanol/water), High Performance Liquid Chromatography (HPLC) Method)
Version / remarks:
4 March 2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
Version / remarks:
August 1996
Deviations:
no
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
- Purity/Composition correction factor: No correction factor required
Analytical method:
other: ultra performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
2.8
pH:
7
Remarks on result:
other: ambient temperature assumed (20 °C)
Details on results:
CALCULATION METHOD
- Pow Calculation: The Pow of the test material was calculated to be 1.1 x 10² (log Pow 2.0) using the Rekker calculation method.
- pKa Values: No pKa values for acidic and basic groups in the molecular structure of the test material in the logarithm range of 1 - 14 were calculated.

HPLC METHOD
In the chromatogram of the test solution, one major test material peak was observed.
The results of the HPLC method are provided below. The calibration curve of the log k’ of the reference substances as function of log Pow is attached.
The equation of the regression line was: log k’ = 0.367 x log Pow – 0.924 (r = 0.993, n = 12).

Pow of the Test Material

Retention time (min)

log pow

Pow

Substance

tr,1

tr,2

mean

Formamide (t0)

0.634

0.632

0.633

Benzylalcohol

0.810

0.809

1.1

Nitrobenzene

0.992

0.990

1.9

Toluene

1.562

1.561

2.7

1,4-Dichlorobenzene

2.013

2.012

3.4

Biphenyl

2.689

2.687

4.0

1,2,4-Trichlorobenzene

3.098

3.095

4.2

Test material - peak 1

1.460

1.456

1.458

2.8

6.8 x 10²

Conclusions:
Under the conditions of the study the log Pow of the test material was determined to be 2.8 at neutral pH. The Pow was determined to be 6.8 x 10².
Executive summary:

The partition coefficient of the test material was investigated in a study which was conducted in accordance with the standardised guidelines OECD 117, EU Method A.24 and EPA OPPTS 830.7570, under GLP conditions, following the HPLC Method.

Under the conditions of the study the log Pow of the test material was determined to be 2.8 at neutral pH. The Pow was determined to be 6.8 x 10².

Description of key information

Under the conditions of the study the log Pow of the test material was determined to be 2.8 at neutral pH. The Pow was determined to be 6.8 x 10².

Key value for chemical safety assessment

Log Kow (Log Pow):
2.8
at the temperature of:
20 °C

Additional information

The partition coefficient of the test material was investigated in a study which was conducted in accordance with the standardised guidelines OECD 117, EU Method A.24 and EPA OPPTS 830.7570, under GLP conditions, following the HPLC Method. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).

Under the conditions of the study the log Pow of the test material was determined to be 2.8 at neutral pH. The Pow was determined to be 6.8 x 10².