Registration Dossier

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report Date:
2020

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
227 °C
Atm. press.:
1 009 mBar

Any other information on results incl. tables

Measured resuts in detail:

 Test run no. lowest temperture (°C)   quantity of sample (ml)
 1st test series 234  0.19 
 2nd test series  235  0.19
 3rd test series  235  0.19

The tests were performed at an atmospheric pressure of 1009 mbar - 1009 mbar.

From these test runs a corrected* minimum ignition temperature of 227 °C results.

* Correction performed according to DIN EN ISO/IEC 80079-20-1.