Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24.04.2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Sample is a Pyrolysis oil from waste rubbers and tires manufactured by Reoil Sp. z o.o.
Batch number: PO_200423_K3
Sample collection: 23/04/2020
Key result
Flash point:
22 °C
Atm. press.:
1 013 hPa
Interpretation of results:
Category 2 (highly flammable liquids) based on GHS criteria
Conclusions:
Due to flash point < 23°C and initial boiling point > 35°C, the substance is classified as H225: Highly flammable liquid and vapour.

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
22 °C