First-aid measures

Emergency measure - Inhalation: Remove victim to fresh air. If cough or other respiratory

symptoms develop seek medical attention immediately. If not

breathing, give artificial respiration.

Emergency measure - Eyes: Immediately flush with copious amounts of water for at least

15 minutes. If irritation persists seek medical attention.

Emergency measure - Skin: Wash materials off the skin with soap and water. If

irritation persists seek medical attention.

Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water fog, foam, dry chemical and carbon dioxide.

Product arising from burning: The substance is combustible and will burn if involved in a

fire, evolving noxious fumes (eg oxides of carbon). However,

there is no  experimental evidence to identify the

anticipated combustion products.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.

Wear appropriate personal protective equipment conforming to

the relevant national or international standards as

mentioned in section 2.3.10.

Absorb spillages with a suitable inert material (eg sand or

soil). Carefully transfer the spillage to waste

containers, or use a sealed industrial vacuum machine.

Containers filled with waste material must be labelled in

the same way as the original containers.

Clean the spillage area with water and detergent.

Dispose of waste material by incineration or landfill in

accordance with local regulations.

Handling and storage

Handling: The substance should be stored, handled and used in

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure.

Engineering controls are necessary to reduce exposure to the

substance.

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical resistant clothing to Standard EN368

Eye protection to Standard EN166

When necessary appropriate respiratory protection should be

used. e.g. an organic vapour mask conforming to EN405 FFA1.

The standards mentioned above should be regarded as a

minimum.

Storage: Store in a cool, dry, well-ventilated area.

Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: 200 kg steel can.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None
Transport: No specific recommendations.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known.

Chemical reaction with water: None

Dust explosion: Not applicable.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will be minimal. Recovery from

minor spillages or accidental discharge is not economically

or technically feasible, and such waste material will be

disposed of by incineration or landfill. In principle, it

may be possible to recover larger spillages of

uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: Not known.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of solutions mixed with

inert material (eg sand or soil) may be disposed of by

landfill at an authorised tip in accordance with local

regulations.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning

under controlled conditions at a licensed waste treatment

processor in accordance with local regulations. Stack gases

must be scrubbed, because noxious fumes (eg oxides of

carbon and sodium-containing compounds) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to

the sewage system or the aqueous environment.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: The substance should not be discharged directly to the

sewage system or the aqueous environment.