Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Reaction mass of diammonium (2R,3R)-2,3-dihydroxybutanedioate and diammonium bis[(2R,3R)-2,3-dioxidobutanedioato]diantimonate(2-)
EC Number:
943-693-3
IUPAC Name:
Reaction mass of diammonium (2R,3R)-2,3-dihydroxybutanedioate and diammonium bis[(2R,3R)-2,3-dioxidobutanedioato]diantimonate(2-)
Test material form:
liquid
Details on test material:
- Name.of test material: Ammonium bis (tartrato) diantimonate (I) solution
- Purity: Water 55%, Ammonium bis (tartrato) diantimonate (1) 27%, Diammonium tartrate 19%
- Batch No.: 150492F03
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Name.of test material: Ammonium bis (tartrato) diantimonate (I) solution
- Purity: Water 55%, Ammonium bis (tartrato) diantimonate (1) 27%, Diammonium tartrate 19%
- Batch No.: 150492F03

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
> 650 °C
Atm. press.:
1 013.25 hPa

Any other information on results incl. tables

Results:

Test run no.

lowest temperature leading to auto ignition

[°C]

quantity of sample

[ml]

ignition delay time

[s]

1sttest series

> 650

-

-

The tests were performed at an atmospheric pressure of 1012 mbar - 1021 mbar.

No auto-ignition temperature detected until the maximum temperature of the test rnethod.

Applicant's summary and conclusion