Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 August 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
yes
Remarks:
The test was performed from the VDO06205A batch, because the ABT01059A batch was expired before the start of the test. This deviation does not have any effect on the overall study conclusions.
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: MINIFLASH FLP, Grabner Instruments, Austria
Key result
Remarks on result:
other: No flash point was observed up to 200 °C

Preliminary test was performed from 30 to 200 °C. No flash point was observed up to 200 °C

The test item was measured in the main test with two parallel tests from 190 °C.

No flash point was observed ofExtract of Chardon marie without supportup to 200 °C.

Interpretation of results:
GHS criteria not met
Conclusions:
In the course of this study an important physico-chemical property, the flash point of test item was determined. The flash point provides a simple, convenient index for assessing the flammability of a wide variety of materials.
The test was performed by use of a MINIFLASH automatic flash point tester with the continuously closed cup – electric arc method according to ASTM D 6450.
No flash point was observed of Extract of Chardon marie without support up to 200 °C.

Description of key information

No flash point was observed of Extract of Chardon marie without support up to 200 °C.

Key value for chemical safety assessment

Additional information

In the course of this study an important physico-chemical property, the flash point of test item was determined. The flash point provides a simple, convenient index for assessing the flammability of a wide variety of materials.

The test was performed by use of a MINIFLASH automatic flash point tester with the continuously closed cup – electric arc method according to ASTM D 6450.

No flash point was observed of Extract of Chardon marie without support up to 200 °C.