Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 825-571-0 | CAS number: 60428-79-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- other: EU Method A.24 (Partition Coefficient (n-octanol / water), HPLC Method)
- Version / remarks:
- December 2015 (REG (EC) No. 440/2008 amended by REG (EC) No. 2016/266)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Version / remarks:
- April 2004
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
- Version / remarks:
- August 1996
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Key result
- Type:
- log Pow
- Partition coefficient:
- 7.5
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- not measured/tested
- Remarks:
- extrapolated value after re-evaluation (see attached report: "Estimation of the bioconcentration factor of Sakuralube S-600").
- Type:
- log Pow
- Partition coefficient:
- > 7.2
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: note: the temperature refers to the column temperature
- Details on results:
- In the chromatogram of the test item solution, two peaks with a retention time of 22.4 and 22.8 minutes were observed. Under the same analytical conditions, the retention time of benzo[ghi]perylene (log Pow = 7.2) was 18.1 minutes. Thus, it was concluded that the log Pow of test item was > 7.2.
For details see attached document "S-600 - Log Pow.pdf"
In a re-evaluation in December 2021, the log Pow value was accurately determined by extrapolation. Herefore, in accordance with the OECD 117 guideline, a linear correlation between the log of the capacity factor and the log Pow was assumed. For more details on the extrapolation see section “Discussion of the HPLC determination” in the attached report “Extrapolation of the bioconcentration factor Sakuralube S-600”. - Conclusions:
- The extrapolated log Pow value of 7.5 was used for further assessment.
Reference
Description of key information
Extrapolated Log Pow = 7.5 at 35°C (column temperature, HPLC method) (OECD 117, EU A.24, OPPTS 830.7570)
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 7.5
- at the temperature of:
- 35 °C
Additional information
Log Kow (Log Pow) > 7.2 at the temperature of 35°C (column temperature)
Re-Evaluation 2021: Extrapolation of Log Kow = 7.5 (see attached report: "Estimation of the bioconcentration factor of Sakuralube S-600")
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.