Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04.12.2013 to 05.12.2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Siemens AG, Prozess-Sicherheit, Industriepark Höchst, B 596 & B 598, D-65926 Frankfurt am Main, Germany

Test material

Constituent 1
Reference substance name:
Fatty acids, coco derivs. II, reaction products with glycine, potassium salts
EC Number:
942-063-5
Molecular formula:
R-CO-NH-CH2-COOK (Note: "R-CO-" is a fatty acid residue)
IUPAC Name:
Fatty acids, coco derivs. II, reaction products with glycine, potassium salts
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Ajinomoto Co., Inc., 15-1 Kyobashi 1-Chome, Chuo-Ku, Tokyo 1048315, Japan/Batch No.: 130808
- Expiration date of the lot/batch: 07.08.2016
- Purity test date: 24.09.2013

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature (10-30°C)

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing:no

FORM AS APPLIED IN THE TEST (if different from that of starting material): solid

Results and discussion

Relative self-ignition temperature (solids)
Key result
Remarks on result:
other: no self-ignition temperature observed up to 404°C

Applicant's summary and conclusion

Conclusions:
No self-ignition temperature observed up to the maximum test temparature of 404°C.
Executive summary:

The auto-flammability of acylglycinate GCK-12H -T (dry matter) was investigated in a study conducted according to EU Method A.16 (Relative Self-Ignition Temperature for Solids). No self-ignition temperature was observed up to the maximum test temperature of 404°C in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.16.