Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
surface tension
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because surface activity is not a desired property of the material
the study does not need to be conducted because water solubility is below 1 mg/L at 20°C
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
The water solubility of the test item is 0.0106 mg/L (see endpoint 4.8).
According to the guidelines, substances with a water solubility < 1 mg/L need not to be tested. The test on the surface tension of the test item was therefore not required.
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 september 2018 - 08 November 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Version / remarks:
2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7840 (Water Solubility)
Version / remarks:
1998
Deviations:
no
GLP compliance:
yes
Type of method:
column elution method
Key result
Water solubility:
0.001 mg/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
>= 7.4 - <= 7.6
Remarks on result:
other: average of two flow rates
Details on results:
Mean concentration in the water samples (n=10) obtained at the flowrate of 24 mL/h was 0.00036 mg/L. CV = 19%.
Mean concentration in the water samples (n=10) obtained at the flowrate of 12 mL/h was 0.00058 mg/L. CV = 16%.
Mean concentration in the water samples (n=10) obtained at the flowrate of 6 mL/h was 0.00052 mg/L. CV = 23%.
The maximum difference on the mean values at flow rates 24 and 12 mL/h was > 30% (i.e. 47%). The maximum difference on the mean values at flow rates 12 and 6 mL/h was ≤ 30% (i.e. 11%). Therefore the water solubility of the test item is based on the results of the 12 and 6 mL/h samples and is reported as 0.00055 mg/L.

The turbidity of the eluates was < 0.2 NTU. According to this, no undissolved particles were detected in the eluates.

No test item was detected in the samples from the blank column.

Conclusions:
The water solubility of the substance at 20°C was determined to be 0.00055 mg/L.
Executive summary:

The water solubility of the substance was determined using the column elution method in a GLP study according to EC A.6, OECD 105 and OPPTS 830.7840.

Quantification was performed by UPLC-MS/MS. The water solubility of the substance at 20°C was determined to be 0.00055 mg/L (average of two flow rates: 12 mL/h and 6 mL/h).

The coefficient of variation (n=10) was ≤ 30% at both flow rates. The maximum difference on the mean values at both flow rates was ≤ 30%.

The pH of the aqueous samples was 7.6 and 7.4.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion