Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-01-23 to 2018-04-04
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Remarks:
performed analogous to ATSM guideline D.93.
Qualifier:
equivalent or similar to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
Determination of the flash point was perfomed with one test item in duplicate according to SOP-PR-034 which is analogous to ASTM D 93 (Procedure A).
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Test item: Sodium isostearoyl-2-lactylate
IUPAC name: Sodium 2-[ 2-(16-methylheptadecanoyloxy) propanoyloxy] propanoate
Batch No.: 1731200025
Purity: Technically pure
CAS No.: 66988-04-3
Empirical formula: C24H43O6Na
Molecular weight: 450.59 g/mol
Physical state: Honey coloured clear viscous liquid.
Storage conditions: Room temperature in the commercial packaging material
Production date: 2017-11-10
Expiry date: 2018-11-09
Key result
Flash point:
202.5 °C
Atm. press.:
99.6 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item, sodium isostearoyl-2-lactylate, was determined according to SOP-PR-034, which is analogous to ASTM D 93 (Procedure A), by the closed cup method, and was 202.5 °C at an atmopheric pressure of 99.6 kPa.
Executive summary:

The flash point of the test item, sodium isostearoyl-2-lactylate, was determined according to SOP-PR-034, which is analogous to ASTM D 93 (Procedure A), by the closed cup method, and was 202.5 °C at an atmopheric pressure of 99.6 kPa.

Description of key information

The flash point of the test item, sodium isostearoyl-2-lactylate, determined by the closed cup method (ASTM D 93, procedure A) was determined to be 202.5°C at an atmospheric pressure of 99.6 kPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
202.5 °C

Additional information