Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-01-16 to 2017-11-02
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
Well documented guideline study without GLP but in house quality assurance.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Regulation (EC) No 440/2008, method A.9 “Flash Point” (May 2008)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D 3828
Version / remarks:
Standard Test Method ASTM D 3828
Deviations:
no
GLP compliance:
no
Other quality assurance:
other: In house quality assurance system.
Type of method:
closed cup
Flash point apparatus:
other: Eraflash automatic flash point
Specific details on test material used for the study:
Name: TALL OIL PITCH, REACTION PRODUCT WITH TRIETHYLENE GLYCOL
CAS No.: 2135769-54-7 (CAS Number received on the 31 October 2017)
EINECS No.: N/A
IUPAC name: TALL OIL PITCH, REACTION PRODUCT WITH TRIETHYLENE GLYCOL
Batch No.: Labo 16-02
Purity: 100%
Appearance at Room Temperature: Viscous liquid
Colour: Dark brown
Certificate of Analysis: See Appendix 1
Storage Conditions: +2°C to +8°C, under nitrogen and protected from light.
Expiry Date: November 2018
Key result
Flash point:
> 200 °C
Remarks on result:
other: ATM not reported.

The Flash Point of the test item was determined to be > 200°C.

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of Tall oil pitch, reaction product with triethylene glycol was tested using the closed cup method according to EU test method A.9 and the Standard Test Method ASTM D 3828. The Flash Point of the test item was determined to be >200°C.
Executive summary:

The flash point of Tall oil pitch, reaction product with triethylene glycol was tested using the closed cup method according to EU test method A.9 and the Standard Test Method ASTM D 3828. The Flash Point of the test item was determined to be >200°C.

Description of key information

The flash point of Tall oil pitch, reaction product with triethylene glycol was tested using the closed cup method according to EU test method A.9 and the Standard Test Method ASTM D 3828. The Flash Point of the test item was determined to be >200°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
200 °C

Additional information