Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 Jan. - 16 Feb. 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been performed according to OECD and EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Aquapel® 203
- Substance type: yellow fatty liquid
- Physical state: liquid
- Analytical purity: 88.7%
- Lot/batch No.: G11AN059
- Expiration date of the lot/batch: 21 January 2010
- Stability under storage conditions: stable
- Storage condition of test material: at room temperature in the dark

Results and discussion

Any other information on results incl. tables

No flash-point on the test substance was observed at temperatures of < 219°C (i.e. below the reaction and/or decomposition temperature of the test substance).

 

Applicant's summary and conclusion

Conclusions:
The test substance does not produce a flammable vapour/air mixture at temperatures of < 219°C.