Registration Dossier

Administrative data

Endpoint:
flash point, other
Remarks:
the substance is a solid with a low melting point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14 August 2017 to 25 August 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
non-GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Qualifier:
according to
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid
Remarks:
soft solid

Results and discussion

Flash point
Flash point:
264 °C
Atm. press.:
1 010 mBar

Any other information on results incl. tables

Repeat results were 263.0°C and 265.0°C, therefore the result is quoted as the average of these two.

Applicant's summary and conclusion

Conclusions:
The flash point of the substance is 264.0°C