Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air. Symptomatic treatment.
Emergency measure - Eyes: Rinse with plenty of water. If irritation develops seek
medical attention.
Emergency measure - Skin: Remove contaminated clothing. Wash with plenty of water.
Seek medical attention.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water, foam, carbon dioxide and dry powder may be used.

Product arising from burning: Products of combustion may contain oxides and nitrogen,
chlorine containing compounds and hydrogen chloride gas.

Product determined by test: N

Protective equipment: Full protective clothing and a self-contained breathing
apparatus should be worn.

Accidental release measures

Emergency measures in case of spillage: Collect spilt material (see 2.3.1) using an
explosion-protected industrial vacuum cleaner. Wash spill
site with water. Do not allow waste water to enter drains.
Dispose of by incineration at a suitable facility.

Handling and storage

Handling: Observe the usual precautions for handling organic
chemicals. Ensure adequate ventilation. Protective clothing,
gloves, safety goggles and suitable breathing protection

(eg a fine particle dust mask, P3) should be worn.

Storage: Store in tightly closed containers in a cool, dry place.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions. Transport in 70 litre fibre drums
lined with two polyethylene bags.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Finely dispersed particles may form explosive dust clouds.
At temperatures above 65 deg C, there is a potential risk of
hydrogen chloride gas evolution.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not possible.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Recommended method at a suitable facility equipped with a

waste gas treatment to remove nitrogen oxides and hydrogen

chloride gas. (A661)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.