Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-09-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Key result
Percentile:
D50
Mean:
6 µm
Remarks on result:
other: no St. dev. stated
Conclusions:
Mean grain size of the test sample is D50 = 6 µm.
Executive summary:

The particle size distribution is determined by means of laser diffraction with a Malvern Mastersizer 2000. The test is carried out in accordance with ISO 13320.

Mean grain size of the test sample is D50 = 6 µm.

Description of key information

The particle size distribution is determined by means of laser diffraction with a Malvern Mastersizer 2000. The test is carried out in accordance with ISO 13320.

Mean grain size of the test sample is D50 = 6 µm.