Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 17, 2016 - June 23, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Part I: Classification procedures, test methods and criteria relating to explosives of Class 1
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Key result
Parameter:
other: Thermal Stability (J/g)
Remarks:
Energy of exothermic decomposition
Value:
-130
Interpretation of results:
GHS criteria not met
Conclusions:
In the DSC-measurement the energy of the exothermic decomposition of the test item Thiocure® TEMPIC was below the threshold of - 500 J/g. Therefore, no further tests for explosive properties had to be performed. The test item showed no explosive properties.
Executive summary:

In the DSC-measurement the energy of the exothermic decomposition of the test item Thiocure® TEMPIC was below the threshold of - 500 J/g. Therefore, no further tests for explosive properties had to be performed.The test item showed no explosive properties.

Description of key information

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification