Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 Jul 2017 - 14 Jul 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
Version / remarks:
Adopted 29 July 2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: EC Guideline No. 440/2008
Version / remarks:
Part B: Methods for the Determination of Toxicity and other health effects, Guideline B.40 BIS: "In Vitro Skin Corrosion: Human Skin Model Test". Official Journal of the European Union No. L142, 31 May 2008.
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
4-phenylbenzophenone
EC Number:
218-345-2
EC Name:
4-phenylbenzophenone
Cas Number:
2128-93-0
Molecular formula:
C19H14O
IUPAC Name:
{[1,1'-biphenyl]-4-yl}(phenyl)methanone
Test material form:
solid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Batch No.of test material: 20161118
- Expiration date of the lot/batch: 17 November 2017

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature protected from light
- Stability under test conditions: Yes, maximum temperature: 90°C

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Justification for test system used:
Recommended test system in international guidelines (OECD and EC).
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDerm Skin Model
- Tissue batch number(s): 26490

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: All incubations, with the exception of the test item incubation of 3 minutes at room temperature, were carried out at 37.0 ± 1.0°C.

NUMBER OF REPLICATE TISSUES: 2

PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if [complete, e.g. the viability after 3 minutes exposure is less than 50%, or if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is less than 15%.]
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 3-minute exposure: 34.1 mg; 1-minute exposure: 41.2 mg??

NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 50 µl

POSITIVE CONTROL
- Amount(s) applied (volume or weight): 50 µl
- Concentration (if solution): 8N
Duration of treatment / exposure:
3- minutes and 1-hour
Number of replicates:
Two tissues per timepoint.

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
3-minute
Value:
99
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
1-hour
Value:
94
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: yes
- Acceptance criteria met for positive control: yes
- Acceptance criteria met for variability between replicate measurements: yes
- Range of historical values if different from the ones specified in the test guideline: yes

Any other information on results incl. tables

Mean Absorption in the in vitro Skin Corrosion Test

   3 -minute application           1 -hour application         
   A (OD570)  B (OD570)  Mean (OD570)  SD   A (OD570)   B (OD570)   Mean (OD570)   SD
 Negative control  1.622  1.712  1.667  ± 0.063  1.666  1.821  1.744  ± 0.11
 Substance  1.587  1.711  1.649  ± 0.088  1.603  1.658  1.630  ± 0.039
 Positive control  0.114  0.109  0.112  ± 0.004  0.18  0.155  0.168 ± 0.018

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The substance is not corrosive in the in vitro skin corrosion test under the experimental conditions described.
Executive summary:

In an in vitro skin corrosion study human skin tissue (epidermal keratinocytes) was exposed to undiluted substance for 3-minutes and 1-hour. There was 99% and 94% tissue viability following the 3-minutes and 1-hour exposure points, respectively. Resultantly, the test material is considered to be a non-irritant and non-corrosive to skin.