Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 November 2015 - 17 December 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester”
Version / remarks:
2012
Deviations:
no
GLP compliance:
yes
Type of method:
other: modified continuously closed cup
Flash point apparatus:
other: Eraflash (Eralytics, Austria)
Specific details on test material used for the study:
Boiling point of test material: 222°C
Key result
Flash point:
136 °C
Atm. press.:
1 013 hPa

- Test 1: 136°C

- Test 2: 136°C

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the substance was determined to be 136°C.
Executive summary:

The flash point at 1013 hPa was determined using the modified continuously closed cup in a GLP study according to ASTM D7094.

Description of key information

The flash point of the substance was determined to be 136°C (EC A.9, ASTM D7094: modified continuously closed cup).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
136 °C

Additional information