Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Endpoint:
explosive properties of explosives
Type of information:
other: Expert statement
Adequacy of study:
supporting study
Study period:
2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Expert statement following the UN Appendix 6 Screening procedures

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Expert statement.
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
3-morpholinopropylamine
EC Number:
204-590-2
EC Name:
3-morpholinopropylamine
Cas Number:
123-00-2
Molecular formula:
C7H16N2O
IUPAC Name:
3-morpholin-4-ylpropan-1-amine
Test material form:
liquid

Results and discussion

Any other information on results incl. tables

Examination of the structural formula for the sample indicates:

- There are no chemical groups associated with explosive properties .

- The oxygen is not bound in energetic functional groups – it is bound in CO groups which do not possess explosive behaviour. The oxygen balance is -233 – below the criteria for consideration (-200).

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Based on the screening procedure, it is beyond reasonable doubt that the material will not exhibit explosive properties. There are no elements of the screening procedure which begin to suggest that explosive properties may be exhibited by the substance. The conduct of the A14 tests is therefore not considered appropriate.