Registration Dossier

Administrative data

Endpoint:
oxidising solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because there are no chemical groups present in the molecule which are associated with oxidising properties and hence, the classification procedure does not need to be applied
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
According to UN Manual of Tests and Criteria- Appendix 6 "Screening procedures" -Section 6.1.2 (Rev. 6, 2015), the test procedure in Section 34 need not be applied for inorganic substances if the substance does not contain any oxygen or halogen atoms.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion