Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-06-15 to 2016-10-03
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash point tester
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Batch no. 41251
- Expiration date of the lot/batch: 2017-03-01 (taken from Label)

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature
- Stability under test conditions: until 01 March 2017 (nominal expiry date) (taken from label)

FORM AS APPLIED IN THE TEST (if different from that of starting material): Colourless liquid
Key result
Remarks on result:
no flash point - measurement carried out until boiling temperature

In both the tests started at 10°C and the test started at -20°C, no flammable vapour/air mixture was produced up to the temperature at which a pressure error due to boiling of the test item occurred. The test item has no flash point below the boiling point.

Interpretation of results:
other: No Flash-point observed.
Conclusions:
The closed cup method was applied for the determination of the flash-point of the test material (AsahiklinTM AC-2000).

No flash-point was observed.
Executive summary:

The closed cup method was applied for the determination of the flash-point of the test material (AsahiklinTM AC-2000).

 

No flash-point was observed.

Description of key information

The closed cup method was applied for the determination of the flash-point of 1,1,1,2,2,3,3,4,4,5,5,6,6-tridecafluorohexane. No flash-point was observed.

Key value for chemical safety assessment

Additional information

A GLP-compliant study, conducted according to ASTM Guideline D93 (closed cup method) was provided for 1,1,1,2,2,3,3,4,4,5,5,6,6-tridecafluorohexane (Charles River Laboratories Den Bosch BV., 2016a).