Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 13 September 2000 and 7 December 2000.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
Identity: ST463.
Appearance: magenta powder
Storage conditions: room temperature
Batch number: 6558
Expiry date: August 2001
Purity: 99.4%
Date received: 1 August 2000
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
4.2
Temp.:
30 °C
Remarks on result:
other: pH not reported

The below table presents the primary data from which the calibration curve was generated.

Sample

Component

tr(minutes)

K

Log10k

Log10Pow

Standard Run A (t0= 0.853 minutes)

Etyhlbenzoate

3.509

3.114

0.493

2.6

Benzophenone

3.816

3.474

0.541

3.2

Naphthalene

5.548

5.504

0.741

3.6

Benzylbenzoate

6.354

6.449

0.809

4.0

Phenanthrene

10.978

11.870

1.074

4.5

Triphenylamine

25.967

29.967

1.469

4.7

Sample A (t0= 0.860 minutes)

ST463 (test substance)

8.173

8.503

0.930

4.15

Sample B (t0= 0.862 minutes)

ST463 (test substance)

8.246

8.566

0.933

4.16

Standard Run B (t0= 0.860 minutes)

Etyhlbenzoate

3.555

3.134

0.496

2.6

Benzophenone

3.867

3.497

0.544

3.2

Naphthalene

5.638

5.556

0.745

3.6

Benzylbenzoate

6.461

6.513

0.814

4.0

Phenanthrene

11.167

11.985

1.079

4.5

Triphenylamine

26.368

29.660

1.472

5.7

The mean calibration curve produced was: log10Pow = 2.92 log10k + 1.43

where:

k = capacity factor = t'r / t0 = tr - t0 / t0

and t'r = true retention time obtained by substracting deadtime, or t0 if I.D.S. from measured retention time of sample or reference.

The test samples analysied at 516 nm were re-run at 230 nm to obtain deadtime values as I.D.S was not detectable at the original wavelength.

ST463 was thus determined to have a log10Pow value of 4.2

Conclusions:
The test substance was found to have a log10Pow value of 4.2.
Executive summary:

The partition coefficient of the substance was determined using the HPLC method. The study was conducted to OECD Method No.117 amd EEC Method A8.

The test substance was found to have a log10Pow value of 4.2.

Description of key information

The partition coefficient of the substance was determined using the HPLC method. The study was conducted to OECD Method No.117 and EEC Method A8.

The test substance was found to have a log10Pow value of 4.2.

Key value for chemical safety assessment

Log Kow (Log Pow):
4.2
at the temperature of:
30 °C

Additional information