Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 700-701-8 | CAS number: 798556-07-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Short-term toxicity to aquatic invertebrates
Administrative data
Link to relevant study record(s)
- Endpoint:
- short-term toxicity to aquatic invertebrates
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- from January 4, 2016 - January 28, 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 202 (Daphnia sp. Acute Immobilisation Test)
- Version / remarks:
- 2004
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.2 (Acute Toxicity for Daphnia)
- Version / remarks:
- Council Regulation (EC) No. 440/2008 laying down test methods pursuant to Regulation (EC) No. 1907/2006 of the European Parliament and the council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH).
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Analytical monitoring:
- no
- Remarks:
- The test material concentration was not quantified at the start and the end of this study due to the very low water solubility. Because of the low water (calculated 2.64e-6 mg/L), the compound cannot be detected with standard analytical methods.
- Vehicle:
- yes
- Remarks:
- reconstituted water
- Details on test solutions:
- Macro nutrients (mg/L)
CaCI2 •2H20 293.80
MgSO4•7H20 123.30
NaHCO3 64.80
KCI 5.80
Na2SiO3•9H20 10.00
NaNO3 0.27
KH2PO4 0.14
K2HPO4 0.18
Trace elements (mg/L)
B 0.5000
Fe 0.2000
Mn 0.1000
Li, Rb and Sr 0.0500
Mo 0.0250
Br 0.0125
Cu and Zn 0.0063
Co and I 0.0025
Se 0.0010
V 0.0003
Macro nutrients (mg/L)
Na2EDTA • 2H20 2.50
Vitamins (µg/L):
Thiamine 75.00
B12 1.00
Biotin 0.75
- pH: 7.77
Preparation of the Test Item:
The test medium (reconstituted water and test item) was prepared freshly. For that purpose, the calibrated flask with test medium was treated in an ultrasonic device for 1 hour. Subsequently, the preparation was stirred with a magnetic stirrer for further 23 hours. Afterwards, the formulation was passed through a membrane filter with a pore size of 0.2 µm. The filtrate was used for the study. - Test organisms (species):
- Daphnia magna
- Details on test organisms:
- Species: Daphnia magna Straus
Culture conditions: The clone is bred in the laboratories of Merck KGaA.
Parental daphnids are used for reproduction until they are about 6 weeks old. Thereafter, they are replaced by neonates.
Daphnids are kept individually in 100 mL glass vessels containing approximately 60 mL reconstituted water (ELENDT M4 medium) at a water temperature of 20 ± 2 °C and a 16 hour light and 8 hour dark regime to ensure similar conditions as in the experiment. Offspring are removed from the vessels at least twice per week.
Feeding: The parental daphnids are fed ad libitum with unicellular green algae Desmodesmus subspicatus three times per week.
Age: Offspring less than 24 hours old were used for the study.
Acclimation period: same as test
Feeding during test: None - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- yes
- Total exposure duration:
- 48 h
- Test temperature:
- 19.7 - 20.1 °C
- pH:
- 7.77 - 8.07
- Dissolved oxygen:
- 7.69 - 8.03 mg/L
- Nominal and measured concentrations:
- Nominal 100 mg/L
- Details on test conditions:
- TEST SYSTEM
- Test vessel: Glass test tubes
- Type: open
- Material, size, headspace, fill volume: 20 mL glass test tubes containing 20 mL medium
- Aeration: no
- No. of organisms per vessel: 5
- No. of vessels per concentration (replicates): 4
- No. of vessels per control (replicates): 4
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: reconstituted water (ELENDT M4 medium according OECD 202)
- Culture medium different from test medium: no
- Intervals of water quality measurement: at start and end of exposure
OTHER TEST CONDITIONS
- Adjustment of pH: no
- Photoperiod: 16h light / 8h dark
- Light intensity: The mean light intensity measured immediately before start of the study was 688 Lux and 681 Lux at the end of the study.
EFFECT PARAMETERS MEASURED : Immobilisation (daily)
VEHICLE CONTROL PERFORMED: no
RANGE-FINDING STUDY
- Test concentrations: 100 mg/L
- Results used to determine the conditions for the definitive study: no immobilisation observed at 100 mg/L - Reference substance (positive control):
- no
- Remarks:
- No positive control used in this study. The accuracy and reliability of the test method is demonstrated periodically as recommended by guidelines with potassium dichromate.
- Key result
- Duration:
- 24 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 100 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- mobility
- Remarks on result:
- other: EC50 >2.64e-6 mg/L, based on water solubility
- Key result
- Duration:
- 48 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 100 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- mobility
- Remarks on result:
- other: EC50 >2.64e-6 mg/L, based on water solubility
- Details on results:
- An aqueous solution of nominal 100 mg/L of the test item revealed no aquatic toxicity in the test system.
The 48-h EC50 exceeded the water solubility of 2.64e-6 mg/L (nominal >100 mg/L) and, thus, could not be determined in this study.
- Behavioural abnormalities: no
- Other biological observations: no
- Mortality of control: no
- Other adverse effects control: no
- Abnormal responses: no
- Any observations (e.g. precipitation) that might cause a difference between measured and nominal values: no - Results with reference substance (positive control):
- Study design:
The study was performed with the test item Art. 104864 (Potassium dichromate) as positive control to check the sensitivity of the test system as recommended by guidelines.
Groups of Daphnia magna were exposed to different concentrations of the test item in reconstituted water for 48 hours. The daphnids were observed for immobilization, 24 and 48 hours after placing in the test medium. The study comprised of four test vessels per concentration containing five daphnids, i.e., 20 daphnids per concentration. Additionally, one control group (20 daphnids) was used.
Test item concentrations of 0.31, 0.46, 0.69, 1.02 and 1.52 mg/L were used in this study.
Results:
Potassium dichromate is the recommended positive control substance and thus no analysis was carried out.
EC50 values with 95 % confidence intervals:
24h EC50 0.753 mg/L (0.646 – 0.883 mg/L)
48h EC50 0.602 mg/L (0.525 – 0.689 mg/L)
Conclusion:
Under the given experimental conditions, the test item Art. 104864 (Potassium dichromate) showed a 24h EC50 value which was within the range of the published data of 0.6 to 1.7 mg/L (Council Regulation (EC) No. 440/2008) and 0.6 to 2.1 mg/L (OECD Guideline No. 202). - Validity criteria fulfilled:
- yes
- Conclusions:
- Under the conditions of the present study, an aqueous solution of nominal 100 mg/L of the test item revealed no aquatic toxicity in the test system.
The 48-h EC50 was >2.64e-6 mg/L (nominal >100 mg/L) and, thus, could not be determined in this study. - Executive summary:
This study was performed according to GLP and the methods applied are fully compliant with OECD TG 202. Under the conditions of the present study, an aqueous solution of nominal 100 mg/L of the test item revealed no aquatic toxicity in the test system. The 48-h EC50 was >2.64e-6 mg/L (nominal >100 mg/L) and, thus, could not be determined in this study.
Reference
Results
The test item concentration in the reconstituted water was not quantified at the start and the end of this study. Because of the low water solubility (2.64e-6 mg/L), the compound cannot be detected with standard analytical methods and the development of an analytical method with a sufficiently low detection and quantification limit is complex.
Due to the absence of any adverse effects at the saturation concentration, the study was performed without analytical concentration verification.
Daphnids exposed to an aqueous preparation of a nominal concentration of 100 mg/L of the test item were not affected.
For the test item the following EC50 values were determined:
EC50 (24h) >2.64e-6 mg/L (nominal >100 mg/L)
EC50 (48h) >2.64e-6 mg/L (nominal >100 mg/L)
Conclusion
Under the conditions of the present study, an aqueous solution of nominal 100 mg/L of the test item revealed no aquatic toxicity in the test system.The 48h EC50 was >2.64e-6 mg/L (nominal >100 mg/L) and, thus, could not be determined in this study.
Description of key information
Under the conditions of the present study, an aqueous solution of nominal 100 mg/L of the test item revealed no aquatic toxicity in the test system (reference 6.1.3-1).
The 48-h EC50 was >2.64e-6 mg/L (nominal >100 mg/L) and, thus, could not be determined in this study.
Key value for chemical safety assessment
Additional information
This study was performed according to GLP and the methods applied are fully compliant with OECD TG 202 (reference 6.1.3-1). Under the conditions of the present study, an aqueous solution of nominal 100 mg/L of the test item revealed no aquatic toxicity in the test system. The 48-h EC50 was >2.64e-6 mg/L (nominal >100 mg/L) and, thus, could not be determined in this study.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.