Diss Factsheets

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1994

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
GLP compliance:
not specified

Test material

Constituent 1
Reference substance name:
Fatty acids, C16-18 (even numbered), esters with 1,2,3-propanetriol and oligomers
IUPAC Name:
Fatty acids, C16-18 (even numbered), esters with 1,2,3-propanetriol and oligomers

Sampling and analysis

Analytical monitoring:
not specified

Test solutions

Vehicle:
no

Test organisms

Test organisms (species):
activated sludge of a predominantly domestic sewage

Study design

Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h

Test conditions

Nominal and measured concentrations:
5 concentration 100-1000mg/L, geometric factor: 1.8
Reference substance (positive control):
yes
Remarks:
Copper(II) sulfate (pentahydrate)

Results and discussion

Effect concentrationsopen allclose all
Duration:
3 h
Dose descriptor:
NOEC
Effect conc.:
1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
growth inhibition
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
growth inhibition

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
In an OECD209 test no toxicity to activated sludge could be determined up to a nominal concetration of 1000 mg/L (3h).
Executive summary:

In an OECD209 test no toxicity to activated sludge could be determined up to a nominal concetration of 1000 mg/L (3h).