Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Remarks:
ISO 9001:2008
Type of method:
equilibrium method
Key result
Flash point:
85 °C
Atm. press.:
95.1 kPa

Test

Test series 1 temperature [°C]

Result yes(+) / no(-)

Test series 2 temperature [°C]

Result yes(+) / no(-)

1

77

-

78

-

2

79

-

79

-

3

80

-

80

-

4

81

-

81

-

5

82

-

82

-

6

83

+

83

+

7

83

+

83

+

 

Test series

Measured value [°C]

Corrected value [°C]

1

83

84.6

2

83

84.6

 

Mean value*

85.0 °C

*The mean value is calculated from test 1 and 2 and rounded to ± 0.5 °C

Determination of the corrected flash-point:

Tc = T0 + 0.25 x (101.3 – p)

TC = corrected flash point to the standard atmospheric pressure (101.3 kPa)  T0 = measured flash point at actual atmospheric pressure  p = actual atmospheric pressure [kPa]

Conclusions:
A flash point of 85.0°C was determined in a reliable study conducted according to an appropriate test protocol, and in compliance with ISO 9001:2008. The result is considered to be reliable.

Description of key information

  Flash point 85.0 °C (EU Method A.9)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
85 °C

Additional information

A measured flash point value of 85.0 °C was determined for the substance using an equilibrium method in accordance with EU Method A.9 and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable and is selected as key study.