Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
UN Recommendations on the Transport of Dangerous Goods
Deviations:
no
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
(8R,9S,10R,13S,14S,17R)-10,13-Dimethyl-1,8,9,10,11,12,13,14,15,16-decahydro-3'H-spiro[cyclopenta[a]phenanthrene-17,2'-furan]-3,5'(2H,4'H)-dione - 2,3,5,6-tetrachlorobenzene-1,4-diol (1:1)
EC Number:
926-987-6
Molecular formula:
C22H28O33.C6H2Cl4O2
IUPAC Name:
(8R,9S,10R,13S,14S,17R)-10,13-Dimethyl-1,8,9,10,11,12,13,14,15,16-decahydro-3'H-spiro[cyclopenta[a]phenanthrene-17,2'-furan]-3,5'(2H,4'H)-dione - 2,3,5,6-tetrachlorobenzene-1,4-diol (1:1)

Results and discussion

Flammable solidsopen allclose all
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: non-flammable
Test procedure:
burning rate test over 100 mm length
Remarks on result:
other: Burning rate test was not performed because of the result of the preliminary test.

Any other information on results incl. tables

.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Conclusions:
The substance should not be considered as flammable and no further testing is required. According to the GHS criteria the measured substance cannot be classified.