Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 February 2017 - 12 May 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM International, ASTM D7094: "Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester", 2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: United Nations (UN), UN no. ST/SG/AC.10/11/Rev.6: Recommendations of the Transport of Dangerous Goods, Part III: Classification Procedures, Test Methods and Criteria Relating to Class 2, Class3, Class 4, Division 5.1, Class 8 and Class 9
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester

Test material

Constituent 1
Chemical structure
Reference substance name:
1-benzyl-4-piperidone
EC Number:
222-782-4
EC Name:
1-benzyl-4-piperidone
Cas Number:
3612-20-2
Molecular formula:
C12H15NO
IUPAC Name:
1-benzylpiperidin-4-one
Test material form:
liquid
Details on test material:
- Identification: JNJ-728195-AAA
- Physical state: liquid
- Appearance: clear yellowish liquid
Specific details on test material used for the study:
- Batch n°: I15EB2027
- Analytical purity: 99.6% (based on base titration)
- Expiration date: 2017-07-25
- Storage condition: at room temperature

Results and discussion

Flash point
Flash point:
150 °C
Remarks on result:
other: the difference between the results obtained with 2 tests was =<6°C. Therefore, it was concluded that the flash-point of the test item is the lowest flash-point obtained

Any other information on results incl. tables

Test

Flash-point

[°C]

Lowest flash-point

[°C]

 

 

 

1

150

150

2

152

 

 

 

 

The difference between the results obtained with 2 tests was =<6°C. Therefore, it was concluded that the flash-point of the test item is the lowest flash-point obtained (150°C).

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of JNJ-728195-AAA (T000015).
The flash-point of the test item was 150°C.