Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Acute Toxicity: inhalation

Currently viewing:

Administrative data

Endpoint:
acute toxicity: inhalation
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
documentation insufficient for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1975
Report date:
1975

Materials and methods

Principles of method if other than guideline:
Inhalation risk test, where rats were exposed for 8 h to air saturated with vapour of the test substance at 20 °C.
GLP compliance:
no
Remarks:
study performed prior to implementation of GLP
Test type:
other: inhalation risk test (IRT)

Test material

Constituent 1
Chemical structure
Reference substance name:
4-tert-butylcyclohexanol
EC Number:
202-676-4
EC Name:
4-tert-butylcyclohexanol
Cas Number:
98-52-2
Molecular formula:
C10H20O
IUPAC Name:
4-tert-butylcyclohexan-1-ol

Test animals

Species:
rat
Strain:
not specified
Sex:
not specified

Administration / exposure

Route of administration:
inhalation: vapour
Type of inhalation exposure:
not specified
Vehicle:
air
Details on inhalation exposure:
GENERATION OF TEST ATMOSPHERE / CHAMBER DESCRIPTION
A saturated vapour atmosphere was generated by passing air through a 5 cm thick layer of test substance at 20 °C.
Analytical verification of test atmosphere concentrations:
not specified
Duration of exposure:
8 h
Concentrations:
ca. 0.221 mg/L (QSAR; Danish EPA Database, 2004; saturated vapour concentration at 20 °C).
No. of animals per sex per dose:
12
Control animals:
not specified
Details on study design:
- Necropsy of survivors performed: yes
- Other examinations performed: clinical signs

Results and discussion

Effect levels
Sex:
not specified
Dose descriptor:
LC50
Effect level:
> 0.221 mg/L air
Based on:
test mat.
Exp. duration:
8 h
Remarks on result:
other: max. saturated vapour concentration
Mortality:
No mortality occurred.
Clinical signs:
other: No clinical signs were observed.
Gross pathology:
There were no findings at pathology.

Applicant's summary and conclusion

Conclusions:
No mortality and no systemic effects were noted in rats exposed to a saturated vapour atmosphere (at 20 °C) for 8h. Based on these results, the LC50 value was assumed to be greater than 0.221 mg/L (max. saturated vapour concentration). Only limited information on test method (e.g. test animals, inhalation exposure etc.) is provided and thus documentation is insufficient for assessment.