Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Qualifier:
no guideline followed
Principles of method if other than guideline:
The particle size distribution of sample was measured using a Cilas 1064 Particle Analyzer
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of distribution:
mass based distribution
Percentile:
D10
Mean:
22.46 µm
Remarks on result:
other: Standard deviation is not available from the instrument.
Percentile:
D50
Mean:
61.81 µm
Remarks on result:
other: Standard deviation is not available from the instrument.
Percentile:
D95
Mean:
110.28 µm
Remarks on result:
other: Standard deviation is not available from the instrument.
Conclusions:
Mean diameter of particles size for 2-hydroxyethyliminodi(acetic acid) was determined to be 61.86 µm using laser scattering/diffraction method.
Executive summary:

Mean diameter of particles size for 2-hydroxyethyliminodi(acetic acid) was determined to be 61.86 µm using laser scattering/diffraction method.

Description of key information

Mean diameter of particles size for 2-hydroxyethyliminodi(acetic acid) was determined to be 61.86 µm using laser scattering/diffraction method.

Additional information