Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 29, 2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: VDI 2263, Sheet 1
Deviations:
no
GLP compliance:
no
Key result
Parameter:
other: DSC
Remarks:
only a low energy of -10 J/g started at 120°C
Remarks on result:
not thermal sensitive if heated under defined confinement

Description of key information

In a Differential Scanning Calorimeter (DSC) Test only a low energy of -10 J/g started at 120°C was deliberated.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification