Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
other: GB/T 6288-1986 Determination of particle size for granular molecular sieve
GLP compliance:
no
Type of method:
sieving
Type of distribution:
mass based distribution
Mass median aerodynamic diameter:
>= 0.18 - <= 0.85 mm
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
No.:
#1
Size:
> 0.18 mm
Distribution:
ca. 91.6 %
No.:
#2
Size:
<= 0.18 mm
Distribution:
ca. 8.4 %
Conclusions:
Based on the test results, the particle size with most amount of sample was 0.18mm~0.85mm, parallel tests were taken, and the weight contents of screen residue with size larger than 0.18 mm were 92.95% and 90.15%, the average result was 91.6%.

Description of key information

Additional information

Based on the test results, the particle size with most amount of sample was 0.18mm~0.85mm, parallel tests were taken, and the weight contents of screen residue with size larger than 0.18 mm were 92.95% and 90.15%, the average result was 91.6%.