Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 January 2016 to 17 August 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
counted distribution
Specific details on test material used for the study:
Batch number: 408291
Percentile:
D10
Mean:
ca. 33 µm
Remarks on result:
other: mean of two results only
Key result
Percentile:
D50
Mean:
ca. 280 µm
Remarks on result:
other: mean of two results only
Percentile:
D90
Mean:
ca. 600 µm
Remarks on result:
other: mean of two results only
Conclusions:
Chelest PC-45 was determined to have d(0.1), d(0.5) and d(0.9) values of 33, 280 and
600 µm respectively.

Description of key information

The test substance was determined to have d (0.1), d (0.5) and d (0.9) values of 33, 280 and

600 µm respectively.

Additional information