Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Type of information:
other: prediction based on chemical structure.
Adequacy of study:
key study
Study period:
2015-04-08 - 2015 -05-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
The department of health of the government of the United Kingdom
Contact with:
other: General prediction based on chemical structure.
Key result
Sample tested:
other: No structural alerts are within the structure
Parameter:
other: No structural alerts are within the structure of the test item
Remarks on result:
other: Based on the chemical structure of the test item the result for the oxidizing properties has been predicted negative.
Interpretation of results:
GHS criteria not met
Remarks:
no oxidising properties
Conclusions:
Based on the chemical structure of the test item the result for the oxidizing properties has been predicted negative.
Executive summary:

A prediction concerning oxidizing properties of the test item was performed using a procedure compatible with EU Method A.21. The structure of the test item was assessed for chemical groups that would imply oxidizing properties. Examples of such groups are nitrates, metal oxides, hypofluorites, difluoroaminopolynitroaryls, perchlorates, bromates and iodites. Since the test substance possesses none of the structural alerts within its chemical structure, no oxidizing properties are expected.

Description of key information

A prediction concerning oxidizing properties of the test item was performed using a procedure compatible with EU Method A.21 (Tremain, 2016). The structure of the test item was assessed for chemical groups that would imply oxidizing properties. Examples of such groups are nitrates, metal oxides, hypofluorites, difluoroaminopolynitroaryls, perchlorates, bromates and iodites. Since the test substance possesses none of the structural alerts within its chemical structure, no oxidizing properties are expected.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification

Based on the chemical structure of the test item the result for the oxidizing properties has been predicted negative.