Registration Dossier

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27.4.2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Non GLP

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid
Details on test material:
Batch No UU09052164
Purity: 97.7%

Results and discussion

Flash point
Key result
Flash point:
86 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Conclusions:
The flash point was determined to be 86°C at 101.3 KPa