Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 to 19 August 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
GLP compliance:
no
Type of method:
dynamic method
Key result
Temp.:
20 °C
Vapour pressure:
0.009 hPa
Key result
Temp.:
25 °C
Vapour pressure:
0.014 hPa
Key result
Temp.:
50 °C
Vapour pressure:
0.089 hPa

Results

 

Thermal Stability

The test item showed no thermal effects up to a temperature of 300 °C.

 

Dynamic method: Vapour-liquid equilibrium (VLE)

The vapour pressure was measured in the temperature range of 159.4 to 190.7 °C. The measured vapour pressure values together with the measured temperatures are listed in the table below.

 

Results of the dynamic method

No.

Temperature / °C

Vapour pressure / hPa

Remark

1

159.4

22.9

measured up

2

165.4

30.3

measured up

3

171.8

37.9

measured up

4

180.2

49.9

measured up

5

185.3

59.8

measured up

6

190.7

68.8

measured up

7

188.5

64.3

measured down

8

183.2

56.1

measured down

9

165.0

27.3

measured down

 

From the measured data points of the vapour pressure curve, the constants A, B and C of the Antoine equation were calculated:

 

Antoine equation

 

Log10 ρ = A +  B / ( C + θ )

 

A = 10.5113

B = -3090.34

C = 273.15.

 

 

Final Results

The vapour pressure of the test item was calculated by extrapolation of the measured vapour pressure curve for the temperatures 20, 25 and 50 °C, according to Regulation EC No. 440/2008 Method A.4.

 

Temperature / °C

Vapour pressure / hPa

20

0.009

25

0.014

50

0.089

 

Conclusions:
Vapour pressure values of 0.009 hPa (at 20 °C), 0.014 hPa (at 25 °C) and 0.089 hPa (at 50 °C) were determined for the test substance according to E.U. Method A.4.

Description of key information

Vapour pressure: 0.009 hPa at 20 °C, 0.014 hPa at 25 °C and 0.089 hPa at 50 °C (EU Method A.4, dynamic method)

Key value for chemical safety assessment

Vapour pressure:
0.014 hPa
at the temperature of:
25 °C

Additional information

According to Regulation EC No. 440/2008 Method A.4, the vapour pressure values of the test item for the temperatures 20, 25 and 50 °C were calculated by extrapolation of the measured vapour pressure curve.