Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 29 September 2016 to 30 September 2016.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
Version / remarks:
2003
Deviations:
no
Qualifier:
according to guideline
Guideline:
IEC 60079-4 (Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature)
Version / remarks:
1975
Deviations:
no
GLP compliance:
yes
Key result
Auto-ignition temperature:
435 °C
Atm. press.:
>= 1 012.2 - <= 1 013.7 hPa

Table: Results of the auto-ignition temperature measurements

Test

Volume
[µL]

Auto-ignition

temperature

[°C]

Ignition delay

[s]

Colour of the flame

Minimum

auto-ignition

temperature

[°C]

 

 

 

 

 

 

1

70

451

24

Orange

446

 

150

446

13

Orange

 

 

300

457

10

Orange

 

 

 

 

 

 

 

2

60

458

19

Orange

439

 

120

439

17

Orange

 

 

250

456

12

Orange

 

 

 

 

 

 

 

3

80

443

27

Orange

438

 

130

438

17

Orange

 

 

200

453

12

Orange

 

 

 

 

 

 

 

 

Conclusions:
The auto-ignition temperature of the substance at 1012-1014 hPa was determined to be 435°C.
Executive summary:

The auto-ignition temperature of the substance at 1012 - 1014 hPa was determined to be 435°C in a GLP study according to EC A.15, DIN 51794 and IEC 60079-4 .

Description of key information

The auto-ignition temperature of the substance at 1012 - 1014 hPa was determined to be 435°C in a GLP study according to EC A.15, DIN 51794 and IEC 60079-4. 

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
435 °C

Additional information