Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Remarks:
Peer-reviewed assessment report (attached in section 13)
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes
Specific details on test material used for the study:
Purity: 99.2%
Auto-ignition temperature:
>= 234 - <= 244 °C
Remarks on result:
other: no information on atm. pressure given, but standard pressure can be assumed specified
Conclusions:
As information was provided via a peer-reviewed assessment report, it can be considered as sufficiently reliable. Auto-ignition temperature has been determined to be 239 °C ± 5 °C
Executive summary:

In a GLP test according to EU Method A.15 an auto-ignition temperature of 239 ± 5°C has been determined.

Description of key information

Auto flammability was determined to be 239 °C ± 5 °C.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
239 °C

Additional information