Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Principles of method if other than guideline:
The substance is soluble and decomposed in water. Test sample was dispersed in kerosene and applied to Laser Diffraction System to measure particle size distribution.
GLP compliance:
no
Other quality assurance:
other: IO9001
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
counted distribution
Specific details on test material used for the study:
Appearance: Violet powder
Lot No. D2D0609
Purity 100% based on TiCl3 content
Mass median aerodynamic diameter:
>= 9.33 - <= 9.35 µm
Geometric standard deviation:
>= 4.2 - <= 5.7
Key result
Percentile:
D10
Mean:
0.78 µm
St. dev.:
0.1
Key result
Percentile:
D50
Mean:
9.35 µm
St. dev.:
0.02
Key result
Percentile:
D90
Mean:
44.83 µm
St. dev.:
3.29

 

Run 1

Run 2

Average

D[4,3]  μm

16.967

20.567

18.767

Surface area m2/g

2.01

2.33

2.17

Span

4.450

5.474

4.963

Homogeneity

1.36

1.8

1.58

D[3,2] μm

2.981

2.580

2.781

d (0.1) μm

0.849

0.711

0.78

d (0.5) μm

9.356

9.333

9.345

d (90) μm

42.503

51.802

47.153

GSD

4.202

5.704

4.953

 

Conclusions:
The particle size distributions of TiC3-AA were measured two times using Laser Diffraction System. The average values were as follows;
D10; 0.78μm, D50;9.35μm, D90; 47.15μm.
Executive summary:

The particle size distributions of TiC3-AA were measured two times using Laser Diffraction System. The average values were as follows; D10; 0.78μm, D50;9.35μm, D90; 47.15μm.

Description of key information

The particle size distributions of aluminum trititanium dodecachloride (TiCl3 -AA) were measured twice using Laser Diffraction System. The average values were as follows; D10; 0.78μm, D50;9.35μm, D90; 47.15μm.

And its span is from 4.45 to 5.5.

Additional information

Test dispersions were prepared by dispersing test sample into kerosene.